MIH800 Indirect Heater

The MIH800 delivers reliable heat for a wide variety of applications. The robust, heavy-duty steel cabinet stands up to the harshest of conditions while the single axle trailer allows for ease of mobility on the jobsite. Large doors provide easy access for maintenance and operation.

Features may include:

Powerful
  • 1.6 L Isuzu® engine, FT4
  • 800,000 BTU output*
  • Max temperature output 180° F (82° C)
  • 85%+ heater efficiency
  • Durable, steel enclosure
  • 32.8-hour run time on one fuel fill
  • No DEF required
Safe
  • Indirect flame technology produces heat that can be safely ducted into tents, buildings and more
  • Comprehensive safety alarms and shutdowns
  • Burner fire eye shuts off fuel pump if no flame is present
  • Positive air shutdown to prevent runaway engine
  • Lockable cabinet to prevent tampering and theft
  • Rear stabilizing jacks
  • DOT and Transport Canada compliant

Engine

Engine Manufacturer Isuzu®
Engine Model: 3CE1-UGZG1
Emissions EPA Final Tier 4
Cylinder Liners 3
Displacement 97.6 in³ (1.6 L
Engine Power @ 1,800 rpm: 21.1 hp (15.7 kW)
Air Filter Dry Type Cartridge
Aspiration Naturally Aspirated
Cooling Liquid cooled

Fuel System

Fuel Type Diesel

Battery

Battery One GRP24 12V, 720 CCA, Wet Cell Battery

Electric

Alternator Marathon® 282CSL1504
Alternator Output, Maximum 13.5 kW 208V 3-Phase | 20 Amp 110V External Outlet

Operational

Operating Conditions Fuel Consumption Rate (engine + burner): 6.25 gph (23.7 Lph) | Firing Rate: 2.55-5.75 gph (9.65-21.77 Lph) | Heat Produced: 357,000-805,000 BTU/hr | Efficiency: Up to 92%
Run Time Per Tankful Minimum run time: 27.3 hr
Operating Temperature, Maximum Capable Of Operating at -40 to 100 °F (-40 to 37.8 °C) Ambient – Not Considering Derate Factors | Heater Max Temperature: 120 to 180 °F (48.9 to 82.2 °C)
Airflow 2,650–5,500 ft3 /min (75–155.7m3 /min)

Capacities

Fuel Capacity Total: 189 US gal (715.4 L) | Usable: 171 US gal (647.3 L)
Oil capacity 7.1 qt (6.7 L)
Cooling System 6.0 qt (5.7 L)

Weights

Dry Weight 4,900 lb (2,223 kg)
Weight, In Running Order 6,080 lb (2,758 kg)

Features

Features Type: Burner: Riello 40F15 Single Stage Diesel Fuel | LOFA® MC704 Engine Control Panel

Warranty

Warranty 1 year, unlimited hours